全国免费咨询热线4000-188-588

TEL:029-88643194 FAX:029-88611928

压力表dp-100

本文章主要介绍了:压力表dp-100,压力表参数,检修 r410a制冷剂运行压力表,压力表dp-100等信息

数字坡度仪
量程:0-±90o;精度:±0.1o
垂直度测定仪
量程:0mm~500mm;精度:±0.2μm
消火栓测压接头
压力表量程:0MPa~1.6MPa;精度:1.6级
喷水末端试水接头
压力表量程:0MPa~0.6MPa;精度:1.6级
防爆静电电压表
量程:0kV~30kV;精度:±10%
接地电阻测量仪
量程:0ω~1000ω;精度:±2%
绝缘电阻测量仪
量程:1Mω~2000Mω;精度:±2%
数字万用表
可测量交直流电压、电流、电阻、电容等
感烟探测器功能试验器
检测杆高度不小于2.5m,加配聚烟罩,内置电源线;连续工作时间不低于2h
感温探测器功能试验器
(压力表dp-100)

(0~250)kPa
0.02(0.05,0.1,0.2)
(0~400)kPa
0.02(0.05,0.1,0.2)
(0~600)kPa
0.02(0.05,0.1,0.2)
0.02(0.05,0.1,0.2)
(0~1.6)MPa
0.02(0.05,0.1,0.2)
(0~2.5)MPa
0.02(0.05,0.1,0.2)
0.02(0.05,0.1,0.2)
0.02(0.05,0.1,0.2)
(0~10)MPa
0.02(0.05,0.1,0.2)
(0~16)MPa
0.02(0.05,0.1,0.2)
(0~25)MPa
0.02(0.05,0.1,0.2)
(0~40)MPa
0.02(0.05,0.1,0.2)
(0~60)MPa
0.02(0.05,0.1,0.2)
(0~100)MPa
0.05(0.1,0.2)
(0~160)MPa
(0~250)MPa
准确度等级
0.02(0.05)
0.02(0.05,0.1,0.2)
0.02(0.05,0.1,0.2)
(压力表dp-100)

精度等级:
0.2%FS,0.1%FS,0.05%FS,0.02%FS
压力范围:
表压:-100kPa~0~600kPa~260MPa
差压:0~100kPa~3.5MPa
绝压:0~100kPa~60MPa
使用环境:
环境温度:(-20~50)℃;
相对湿度:<95%;
大气压力:(86~106)kPa;
存储温度:(-30~80)℃。
SFTN液晶,白色背光,5位数字显示。液晶显示采用大屏幕段码宽视角液晶显示窗,比以前显示更大、更醒目和直观。
供电方式:
3.6V不可充电锂电池(ER18505H)
安装方式:
三种:径向安装、轴向带安装盘、分体式安装;
表盘直径:100mm。
压力连接:
标准M20*1.5外螺纹接头(可根据用户需要定制);
(压力表dp-100)

(压力表dp-100)

(压力表dp-100)

(4)压力表盘大小应当保证锅炉操作人员能够清楚地看到压力指示,表盘直经应当不小于100mm。
6.2.3压力表校验
压力表安装前应当进行校验,在刻度盘上应当划出指示工作压力的红线,注明下次校验日期。压力表校验后应当加铅封。
6.2.4压力表安装
压力表安装应当符合以下要求:
(1)应当装设在便于观察和冲洗的位置,并且应当防止受到高温、冰冻和震动的影响;
(2)锅炉蒸汽空间设置的压力表应当有存水弯或者或者其它冷却蒸汽的措施,热水锅炉用的压力表也应当有缓冲弯管,弯管内经应当不小于10mm;
(3)压力表与弯管之间应当设置三通阀门,以便吹洗管路、卸换、校验压力表。
(压力表dp-100)

了解更多关于:油压计算推动物体压力表的数值,列车制动时 双针压力表,带边耐震压力表,电接点压力表 yx60,ssi压力表,双针压力表双针代表啥意思,折弯机的压力表,锅炉压力表安全阀点检记录表,压力表的外壳公称直径,数显压力表自来水用,滴灌用什么型号压力表,空调压力表接管,液氮储罐 压力表 安全阀 液位计,上海方俊仪器仪表压力表接线图纸,抽砂管道压力表,yyst压力表是哪个厂家,tec压力表,压力表上的par什表什么,涡轮压力表应该怎样看,压力表精度标准
本文摘自:http://www.oen1718.com 转载请注明出处